Funny you post this today Eric.....I dont have the ability to scan, but I just got the 1000m Autozilla back from service and it to was tested with the following results

Sampling time: 60 out of 60 seconds

Test Pressure: 19.745 Bar

Initial Strain: -036.2 um

Strain trend: -002.0%um/Minute

Test passed

Not sure how this differs from yours, maybe you can explain the different method used and educate usThumbsUp02.gif Thanks for the always informative posts.